Navigation
Lutron Homeworks 1.33 Interface Instructions
Follow these instructions to create the serial equipment interface on the Lutron Homeworks system (version 1.33 or later) and to assign it to a port. Once this is done, the Lutron processor/boards will push out the updated information through the serial interface to the Cortexa.
Lutron Set-Up
- In the programming menu (view>>programming), go to “Security Programming” (lock on right hand side).
- Go to the Interface Tab, select “Serial Equipment” and then click add. A serial output definition box will appear.
- Name the device as "Cortexa", and use the following configuration:
- *Driver: Generic
- *Baud Rate: 115200
- *Data Bit: 8
- *Parity: None
- *Stop Bits: 1
- *Handshaking: None
- *Monitoring - check Dimmer Levels, Keypad Buttons, Keypad LEDs, GrafikEye
- *Check “Suppress L232 prompt”, and then check “Suppress Modem String” (do not check "Suppress Replies")
- Go to Address Assignments (View>Address Assignments) and do the following:
- *Select appropriate processor (if only one processor, skip this step)
- *Select the desired link, it should say the Link # : (RS232)
- *Select the recently named serial device (named "Cortexa") in the right pane
- *Click in the white area under location to assign the Cortexa to the correct link.
- Save the project
- Upload the modified project to the Processor
- Reboot the processor
Cortexa Set-up
- On the Sub-System setup page, in the HomeWorks entry, select the following:
- *Specify the COM port to which the Lutron system is connected
- *Baud Rate: 115200
- Click “Save” at bottom of page
- Add a lighting device for each Lutron HomeWorks address via the Cortexa’s Device Manager page.